Information about EN ISO 1716

Test method EN ISO 1716, Fire technical testing of building products – Determination of calorific potential.

Main field of application

Classification according to Euroclass A1, A1fl, A1L, A2, A1L, A2fl, and A2L(designation for non-combustible products) according to the European System. Three other test methods are also used, see data sheet EN 13823, EN ISO 9239-1 and EN ISO 1182.

Examples of products that can be tested with this method

Homogenous and multi layered building products, for example insulation products of mineral wool with or without facings, fibre reinforced cement, silicate boards, sealing compounds etc. 

Material consumption during test

For a complete test, a minimum of one test specimen with the dimension 250 mm x 250 mm and the mass 50 g is required.

Test procedure 


A small test specimen with a specified weight is combusted completely during constant volume and oxygen atmosphere inside a high-pressure calometric bomb. The combustion of the test specimen heats up water, whose temperature rise gives a measurement of calorific potential

 

 

 

Related Information

Contact Persons

Marina C Andersson

Phone: +46 10 516 52 92

Per Thureson

Phone: +46 10 516 50 83

RISE Research Institutes of Sweden, Phone 010-516 50 00, E-mail info@ri.se

The RISE institutes SP, Innventia and Swedish ICT have merged in order to become a stronger research and innovation partner for businesses and society.
During 2017 sp.se will be one of several websites within RISE. Please visit ri.se for more information about RISE.

Dela den här sidan: